The pressure differential is manually monitored via the inlet and outlet manometers. An increase in pressure indicates the need for cleaning. To begin, shut off the water supply and depressurize the system. Then, remove the cover and extract the filter cartridge. The cleaning method depends on the filter type. A screen filter element is cleaned directly with pressurized water. For a disc filter, the cartridge’s retaining screw must be loosened to separate the discs for a thorough cleaning with pressurized water. After cleaning, the filter is reassembled and ready for service.

Çalışma Prensibi


Water enters the filter and passes through the filtration element (either a fine screen or a set of discs). During operation, contaminants gradually accumulate on the surface of this element—the inner surface for screens or the outer surface for discs. This buildup obstructs the water flow, creating a pressure differential between the filter’s inlet and outlet. Manual cleaning is required when this pressure differential reaches 0.7 bar.

Mini Screen and Disc Filters

local_offer MPE

AVANTAJLAR

Ekonomik Ekonomik
Atık Su Tasarrufu Atık Su Tasarrufu
Düşük Basınç Kaybı Düşük Basınç Kaybı
Dayanıklı Dayanıklı
Sistem Koruması Sistem Koruması
Kompakt Tasarım Kompakt Tasarım

Maximum Performance. Minimal Space.

Designed for efficiency in tight spaces, Aytok MPD-MPE filters provide a robust and versatile solution for low-flow water systems. They are perfectly suited for applications like garden irrigation, fertigation, and protecting small-scale cooling equipment.

GENEL ÖZELLİKLER

MPE

Body Material PP
Cartridge Material SS304L, PP
Maximum Working Pressure 8 bar ; 116 Psi
Maximum Working Temperature 60 °C ; 140°F
Filtration Sensitivity 80, 100, 130, 200 μ (micron)
CODE D M T D1 H K Flow Rate Filtration Area
cm²
Weight
kg
Inch DN Inch Inch mm mm mm m³/h GPM(US)
MNPE34 3/4 20 - 3/4 68 190 160 5 22 165 0,3
MNPE10 1 25 - 3/4 68 190 160 6 26,4 165 0,3
MDPE10 1 25 - 3/4 96 230 220 10 44 300 0,75
MDPE14 1 1/4 32 - 3/4 96 230 220 13 66 300 0,75
MDPE15 1 1/2 40 - 3/4 96 230 220 15 66 300 0,75
MXPE15 1 1/2 40 1/4 3/4 120 280 270 20 88 515 1,2
MXPE20 2 50 1/4 3/4 120 280 270 25 110 515 1,2

Bize Mesaj Gönderin

Bizimle iletişime geçmek için aşağıdaki formu doldurun.

Ürün Detayı

Mini Screen and Disc Filters

Mini Screen and Disc Filters

local_offer MPE
Damla & Mikro Sulama Damla & Mikro Sulama
Sera Sulaması Sera Sulaması
Peyzaj Sulaması Peyzaj Sulaması
İçme Suyu Ön Filtrasyon İçme Suyu Ön Filtrasyon
Proses & Soğutma Suyu Proses & Soğutma Suyu
Atık Su Geri Dönüşümü Atık Su Geri Dönüşümü

GENEL ÖZELLİKLER

MPE

Body Material PP
Cartridge Material SS304L, PP
Maximum Working Pressure 8 bar ; 116 Psi
Maximum Working Temperature 60 °C ; 140°F
Filtration Sensitivity 80, 100, 130, 200 μ (micron)

Temizlik Süreci

The pressure differential is manually monitored via the inlet and outlet manometers. An increase in pressure indicates the need for cleaning. To begin, shut off the water supply and depressurize the system. Then, remove the cover and extract the filter cartridge. The cleaning method depends on the filter type. A screen filter element is cleaned directly with pressurized water. For a disc filter, the cartridge’s retaining screw must be loosened to separate the discs for a thorough cleaning with pressurized water. After cleaning, the filter is reassembled and ready for service.

Çalışma Prensibi

Water enters the filter and passes through the filtration element (either a fine screen or a set of discs). During operation, contaminants gradually accumulate on the surface of this element—the inner surface for screens or the outer surface for discs. This buildup obstructs the water flow, creating a pressure differential between the filter’s inlet and outlet. Manual cleaning is required when this pressure differential reaches 0.7 bar.

AVANTAJLAR

Ekonomik Ekonomik
Atık Su Tasarrufu Atık Su Tasarrufu
Düşük Basınç Kaybı Düşük Basınç Kaybı
Dayanıklı Dayanıklı
Sistem Koruması Sistem Koruması
Kompakt Tasarım Kompakt Tasarım

Güçlü Filtrasyon, Zeki Tasarım.

Maximum Performance. Minimal Space.

Designed for efficiency in tight spaces, Aytok MPD-MPE filters provide a robust and versatile solution for low-flow water systems. They are perfectly suited for applications like garden irrigation, fertigation, and protecting small-scale cooling equipment.

DÖKÜMANLAR

CODE D M T D1 H K Flow Rate Filtration Area
cm²
Weight
kg
Inch DN Inch Inch mm mm mm m³/h GPM(US)
MNPE34 3/4 20 - 3/4 68 190 160 5 22 165 0,3
MNPE10 1 25 - 3/4 68 190 160 6 26,4 165 0,3
MDPE10 1 25 - 3/4 96 230 220 10 44 300 0,75
MDPE14 1 1/4 32 - 3/4 96 230 220 13 66 300 0,75
MDPE15 1 1/2 40 - 3/4 96 230 220 15 66 300 0,75
MXPE15 1 1/2 40 1/4 3/4 120 280 270 20 88 515 1,2
MXPE20 2 50 1/4 3/4 120 280 270 25 110 515 1,2