Semi Automatic Metal Screen Filter - MF

Aytok Hydrofilt MF filters are a manually cleaned filter group. Cleaning must be done manually by the user. The need for washing is determined by observing the difference between the inlet and outlet pressures. If the pressure difference is increased, cleaning should be done. While washing is being done, the filtering process continues. The dirty water formed during the washing process is discharged from the discharge valve.

General Characteristics

Body Material: S195T / SS 316L / SS 304 L
Screen Material: SS 304L, PA6GFR30
Maximum Working Pressure: 10 Bar (145 PSI)
Minimum Working Pressure: 1 Bar (14.5 PSI)
Maximum Working Temperature : 60 °C (140 °F)
Back Flush Operation Criteria: Time and / or Pressure Differential
Back Flush Controlling Unit : Electronic (AC) Control
Filtration Degree: 20-2000 micron (µ)
Painting Method: Electrostratic Powder Coating
Painting Material: Epoxy Polyester

Technical Specification

CODE INLET/OUTLET A B L1 L D F DRAINAGE FLOW FLOW FILTER SURFACE AREA NOZZLE SIEVE WEIGHT
inch DN mm inch m³/h cm² pieces kg
MF102  CMF102 2 50 390 270 365 910 10 2 12 40 1317 2 2 36         30
MF1025  CMF1025 65 390 270 365 910 10 2 12 50 1317 2 2 37           31
MF103  CMF103 3 80 440 270 465 1010 10 2 18 70 1975 3 3 41          35
MF104  CMF104 4 100 580 270 570 1115 10 2 24 120 2634 4 4 48          42
MF105  CMF105 5 125 680 287 770 1315 10 2 18 150 3951 3 6 57         50
MF106  CMF106 6 150 780 287 970 1515 10 2 24 180 5268 4 8 67           60
MF106S  CMF106S 6 150 880 287 1170 1715 10 2 30 220 6585 5 10 75          68
MF128  CMF128 8 200 870 312 1150 1695 12 2 30 320 6585 5 10 115         104
MF128S CMF128S 8 200 985 312 1385 1930 12 2 36 340 7902 6 12 127       114

 

Working Principle

The water enters to from inlet and passes through the area where the fine screen is located. The clean water is filtered and sent to the outlet pipe. The water then flows to the outlet, the water forms the pollution layer on the inner surface of the screen, and this pollution causes a pressure difference at the inlet and outlet of the filter. This pressure difference must be observed manually from inlet and outlet manometers. In this case, the filter need flushing operation.

By opening the drainage valve, a vacuum effect is created on the collector pipe, which opens to the atmosphere, and suction is provided from the nozzles. After the drainage valve is opened, by manually turning the hand crank connected to the collector, the fine screen surface is completely scanned and the inlet and outlet pressures are equalized. After the equalized inlet and outlet pressures, the drain valve is closed and the flushing operation is completed.

 